Goldway G40E

Bedside patient monitor

Find similar products

Clinicians need to respond swiftly to rapid changes in their patient's condition. Having a highly reliable, versatile patient monitoring solution on hand saves precious time in determining the best course of care. G40E is your choice for a cost-effective, easy to learn, pre-configured bedside monitor that provides reliable measurements (Philips ST/AR ECG and FAST-SpO₂).

Features
Advanced functionalities

Advanced functionalities

To accommodate different clinical environments, the G40E delivers real-time data about cardiac and respiratory conditions. In addition to basic monitoring parameters, such as Philips ST/AR 3- and 5-lead ECG/ respiration, NBP, 2 temperatures, and Philips SpO₂/PR, ST and arrhythmia monitoring, it also provides 2-channel invasive blood pressure and Microstream etCO₂ monitoring as options.

Advanced functionalities

To accommodate different clinical environments, the G40E delivers real-time data about cardiac and respiratory conditions. In addition to basic monitoring parameters, such as Philips ST/AR 3- and 5-lead ECG/ respiration, NBP, 2 temperatures, and Philips SpO₂/PR, ST and arrhythmia monitoring, it also provides 2-channel invasive blood pressure and Microstream etCO₂ monitoring as options.

Advanced functionalities

To accommodate different clinical environments, the G40E delivers real-time data about cardiac and respiratory conditions. In addition to basic monitoring parameters, such as Philips ST/AR 3- and 5-lead ECG/ respiration, NBP, 2 temperatures, and Philips SpO₂/PR, ST and arrhythmia monitoring, it also provides 2-channel invasive blood pressure and Microstream etCO₂ monitoring as options.
Ease of use

Ease of use

The monitor has a 12.1” display with flexible display modes, such as big number display, minitrend, OxyCRG, as well as auto waveform channel height adjustment function to fit various clinical settings. Intuitive menus, fixed key access, bright color screen and optional touchscreen were all designed for maximum ease of use.

Ease of use

The monitor has a 12.1” display with flexible display modes, such as big number display, minitrend, OxyCRG, as well as auto waveform channel height adjustment function to fit various clinical settings. Intuitive menus, fixed key access, bright color screen and optional touchscreen were all designed for maximum ease of use.

Ease of use

The monitor has a 12.1” display with flexible display modes, such as big number display, minitrend, OxyCRG, as well as auto waveform channel height adjustment function to fit various clinical settings. Intuitive menus, fixed key access, bright color screen and optional touchscreen were all designed for maximum ease of use.
Networking and data management

Networking and data management

The G40E comes standard with LAN networking capabilities for facilities looking to create a network with a bi-directional communication with Philips Efficia CMS200 central monitoring system or require data output in HL7 format.

Networking and data management

The G40E comes standard with LAN networking capabilities for facilities looking to create a network with a bi-directional communication with Philips Efficia CMS200 central monitoring system or require data output in HL7 format.

Networking and data management

The G40E comes standard with LAN networking capabilities for facilities looking to create a network with a bi-directional communication with Philips Efficia CMS200 central monitoring system or require data output in HL7 format.
Compact and cost-effective

Compact and cost-effective

Built according to Philips exacting quality standards, the G40E patient monitor offers market-proven essential parameters in a compact, cost-effective monitor to provide accurate measurement results upon your tight budget. The alarm latch function helps reduce alarm fatigue to form a silent care environment.

Compact and cost-effective

Built according to Philips exacting quality standards, the G40E patient monitor offers market-proven essential parameters in a compact, cost-effective monitor to provide accurate measurement results upon your tight budget. The alarm latch function helps reduce alarm fatigue to form a silent care environment.

Compact and cost-effective

Built according to Philips exacting quality standards, the G40E patient monitor offers market-proven essential parameters in a compact, cost-effective monitor to provide accurate measurement results upon your tight budget. The alarm latch function helps reduce alarm fatigue to form a silent care environment.
Works with Efficia consumables

Works with Efficia consumables

The G40E patient monitor is designed to be compatible with Philips Efficia consumables, which are also used on Philips Efficia CM series patient monitors, to lower your total cost of ownership by sharing Philips consumables across different care settings.

Works with Efficia consumables

The G40E patient monitor is designed to be compatible with Philips Efficia consumables, which are also used on Philips Efficia CM series patient monitors, to lower your total cost of ownership by sharing Philips consumables across different care settings.

Works with Efficia consumables

The G40E patient monitor is designed to be compatible with Philips Efficia consumables, which are also used on Philips Efficia CM series patient monitors, to lower your total cost of ownership by sharing Philips consumables across different care settings.
  • Advanced functionalities
  • Ease of use
  • Networking and data management
  • Compact and cost-effective
See all features
Advanced functionalities

Advanced functionalities

To accommodate different clinical environments, the G40E delivers real-time data about cardiac and respiratory conditions. In addition to basic monitoring parameters, such as Philips ST/AR 3- and 5-lead ECG/ respiration, NBP, 2 temperatures, and Philips SpO₂/PR, ST and arrhythmia monitoring, it also provides 2-channel invasive blood pressure and Microstream etCO₂ monitoring as options.

Advanced functionalities

To accommodate different clinical environments, the G40E delivers real-time data about cardiac and respiratory conditions. In addition to basic monitoring parameters, such as Philips ST/AR 3- and 5-lead ECG/ respiration, NBP, 2 temperatures, and Philips SpO₂/PR, ST and arrhythmia monitoring, it also provides 2-channel invasive blood pressure and Microstream etCO₂ monitoring as options.

Advanced functionalities

To accommodate different clinical environments, the G40E delivers real-time data about cardiac and respiratory conditions. In addition to basic monitoring parameters, such as Philips ST/AR 3- and 5-lead ECG/ respiration, NBP, 2 temperatures, and Philips SpO₂/PR, ST and arrhythmia monitoring, it also provides 2-channel invasive blood pressure and Microstream etCO₂ monitoring as options.
Ease of use

Ease of use

The monitor has a 12.1” display with flexible display modes, such as big number display, minitrend, OxyCRG, as well as auto waveform channel height adjustment function to fit various clinical settings. Intuitive menus, fixed key access, bright color screen and optional touchscreen were all designed for maximum ease of use.

Ease of use

The monitor has a 12.1” display with flexible display modes, such as big number display, minitrend, OxyCRG, as well as auto waveform channel height adjustment function to fit various clinical settings. Intuitive menus, fixed key access, bright color screen and optional touchscreen were all designed for maximum ease of use.

Ease of use

The monitor has a 12.1” display with flexible display modes, such as big number display, minitrend, OxyCRG, as well as auto waveform channel height adjustment function to fit various clinical settings. Intuitive menus, fixed key access, bright color screen and optional touchscreen were all designed for maximum ease of use.
Networking and data management

Networking and data management

The G40E comes standard with LAN networking capabilities for facilities looking to create a network with a bi-directional communication with Philips Efficia CMS200 central monitoring system or require data output in HL7 format.

Networking and data management

The G40E comes standard with LAN networking capabilities for facilities looking to create a network with a bi-directional communication with Philips Efficia CMS200 central monitoring system or require data output in HL7 format.

Networking and data management

The G40E comes standard with LAN networking capabilities for facilities looking to create a network with a bi-directional communication with Philips Efficia CMS200 central monitoring system or require data output in HL7 format.
Compact and cost-effective

Compact and cost-effective

Built according to Philips exacting quality standards, the G40E patient monitor offers market-proven essential parameters in a compact, cost-effective monitor to provide accurate measurement results upon your tight budget. The alarm latch function helps reduce alarm fatigue to form a silent care environment.

Compact and cost-effective

Built according to Philips exacting quality standards, the G40E patient monitor offers market-proven essential parameters in a compact, cost-effective monitor to provide accurate measurement results upon your tight budget. The alarm latch function helps reduce alarm fatigue to form a silent care environment.

Compact and cost-effective

Built according to Philips exacting quality standards, the G40E patient monitor offers market-proven essential parameters in a compact, cost-effective monitor to provide accurate measurement results upon your tight budget. The alarm latch function helps reduce alarm fatigue to form a silent care environment.
Works with Efficia consumables

Works with Efficia consumables

The G40E patient monitor is designed to be compatible with Philips Efficia consumables, which are also used on Philips Efficia CM series patient monitors, to lower your total cost of ownership by sharing Philips consumables across different care settings.

Works with Efficia consumables

The G40E patient monitor is designed to be compatible with Philips Efficia consumables, which are also used on Philips Efficia CM series patient monitors, to lower your total cost of ownership by sharing Philips consumables across different care settings.

Works with Efficia consumables

The G40E patient monitor is designed to be compatible with Philips Efficia consumables, which are also used on Philips Efficia CM series patient monitors, to lower your total cost of ownership by sharing Philips consumables across different care settings.

Specifications

ECG
ECG
Lead type
  • 3-lead or 5-lead selectable
Lead selection, 3-lead
  • I, II, III
Lead selection, 5-lead
  • I, II, III, aVR, aVL, aVF, V
HR measurement
  • Adult / pediatric: 15 bpm - 300 bpm Neonatal: 15 bpm - 300 bpm Step: 1 bpm
HR accuracy
  • ±5 bpm or ±1 %, whichever is greater
Arrhythmia
  • 21 calls
ST measurement range
  • -2.5 mV - +2.5 mV
Waveform speed
  • 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s
Gain selection
  • x 1/4, x 1/2, x 1, x 2, x 4, Auto
Pacemaker detection
  • Yes
Protection
  • Against electrosurgical interference and defibrillation
Non-invasive blood pressure (NBP)
Non-invasive blood pressure (NBP)
Method
  • Automatic oscillometric
Parameters
  • SYS/DIA/MAP/Pulse Rate
Operating mode
  • Manual/Auto/STAT
Auto measure intervals
  • 3, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes
Units
  • mmHg/kPa
Cuff pressure range, adult / pediatric
  • 0 - 300 mmHg ( 0 kPa - 40.0 kPa)
Cuff pressure range, neonate
  • 0 - 150 mmHg ( 0 kPa - 20.0 kPa)
Systolic measurement range, adult/ pediatric
  • 30 mmHg - 254 mmHg (4.0 kPa - 33.9 kPa)
Systolic measurement range, neonate
  • 30 mmHg - 135 mmHg (4.0 kPa - 18.0 kPa)
Diastolic measurement range, adult / pediatric
  • 10 mmHg - 220 mmHg (1.3 kPa - 29.3 kPa)
Diastolic measurement range, neonate
  • 10 mmHg - 110 mmHg (1.3 kPa - 14.7 kPa)
MAP measurement range, adult / pediatric
  • 20 mmHg – 235 mmHg (2.7 kPa – 31.3 kPa)
MAP measurement range, neonate
  • 20 mmHg – 125mmHg (2.7 kPa – 16.7kPa)
Accuracy, maximum standard deviation
  • 8 mmHg (1.1 kPa)
Accuracy, mean error
  • ±5 mmHg (±0.7 kPa)
Pulse rate range
  • 40 bpm – 240 bpm
Pulse rate accuracy
  • ±5bpm or ±5%, whichever is greater
SpO2 (Philips SpO2 technology)
SpO2 (Philips SpO2 technology)
Measurement range
  • 0 - 100 %
Accuracy
  • 70 % - 100 %, depends on sensor; 0 - 69 %, unspecified
Waveform speed
  • 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Pulse rate range
  • 30 bpm - 300 bpm
Pulse rate accuracy
  • ±2 bpm or ±2%, whichever is greater
Perfusion index
  • Yes
Respiration (RESP)
Respiration (RESP)
Measurement method
  • Thoracic impedance
Measurement range
  • 0 rpm - 150 rpm
Accuracy
  • 0rpm – 120rpm: ±1 rpm; 121rpm – 150rpm: ±2 rpm
Waveform speed
  • 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s Accuracy undefined
Gain selection
  • x 1/2, x 1, x 2
Apnea alarm
  • Yes, 10 - 60 s
Work mode
  • Auto or manual (threshold)
RESP lead
  • RA-LL
Temperature (TEMP, 2-channel)
Temperature (TEMP, 2-channel)
Measurement range
  • 0 - 50℃ (32℉ - 122℉)
Resolution
  • 0.1℃ (0.2℉)
Accuracy
  • ±0.1℃ (±0.2℉) (without sensor)
Units
  • ℃ / ℉
Minimum measuring time
  • Attachable skin surface probe: < 10 minutes Esophageal/rectal probe: < 2 minutes
Capnography (etCO2, optional)
Capnography (etCO2, optional)
Method
  • Microstream, infrared absorption (Oridion)
Parameters
  • awRR, etCO₂, inCO₂
Measurement range
  • 0 - 99 mmHg (0 kPa - 13.2 kPa)
Accuracy+C781, 0 – 38 mmHg (0 kPa – 5.1 kPa)
  • ±2 mmHg (±0.28 kPa)
Accuracy, 39 mmHg – 99 mmHg (5.2 kPa – 13.2 kPa)
  • ± (5% of reading + 0.08% for every 1 mmHg (0.13 kPa) above 38 mmHg (5.1kPa)
awRR range
  • 0-150 rpm
awRR accuracy, 3 rpm – 70 rpm
  • ±1 rpm
awRR accuracy, 71 rpm – 120 rpm
  • ±2 rpm
awRR accuracy, 121 rpm – 150 rpm
  • ±3 rpm
Invasive blood pressure (IBP, 2-channel, optional)
Invasive blood pressure (IBP, 2-channel, optional)
Parameters
  • SYS/DIA/MAP/Pulse Rate
Measurement range
  • -50 - 400 mmHg (-6.6 kPa - 53.3 kPa)
Accuracy
  • ±4 mmHg (0.53 kPa) or ±4 % of reading, whichever is greater
Waveform speed
  • 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Resolution
  • 1 mmHg (0.13 kPa)
Units
  • mmHg/kPa/cmH₂O
Transducer sensitivity
  • 5 uV/V/mmHg
Pulse rate range
  • 30 bpm – 254 bpm
Pulse rate accuracy
  • ±2bpm or ±2%, whichever is greater
Sampling rate
  • 62.5 samples per second
Recorder (optional)
Recorder (optional)
Type
  • Built-in thermal recorder, 3 channels
Print mode
  • Real-time recording, timed recording, alarm-activated recording
Print speed
  • Auto, 12.5 mm/s, 25 mm/s, 50 mm/s
Display
Display
Type
  • Color TFT LCD, 4:3
Size
  • 10.4+611:631"
Resolution
  • 800 x 600 pixels
Channels
  • Max 11 channels (auto waveform channel height adjustment)
Power supply
Power supply
AC power input
  • 100 - 240 VAC, 50/60 Hz
Battery
  • Rechargeable Li-Ion battery Maximum 2.5 hour continuous monitoring
Weight and dimensions
Weight and dimensions
Net weight
  • Approx. 3.5 kg without battery
Dimensions (w x d x h)
  • 316 mm x 265 mm x 131 mm (12.5 in. x 10.5 in. x 5.2 in.)
Safety approval and quality system
Safety approval and quality system
Safety standard
  • IEC 60601-1-2:2014
Electromagnetic environment
  • IEC 60601-1-2:2000/A1:2014
Quality system
  • ISO9001 & ISO13485 certified CE marking according to the Council Directive 93/42/EEC
Water proof
  • IPX1
Data review and storage
Data review and storage
Data review and storage
  • 1600- NBP data, 1200 hr trend graph, 120 min full disclosure ECG 1, 200 - alarm & arrhythmia events
External interface (standard)
External interface (standard)
External interface
  • ECG analog output VGA output Nurse call LAN USB
Cardiac Output (optional)
Cardiac Output (optional)
Measurement method
  • Right heart thermodilution
Measurement range
  • 0.1 l/min - 20.0 l/min
Measurement accuracy
  • ±0.2 l/min or ±10 %, whichever is greater
Blood temperature range
  • 27℃ - 43℃ (80.6℉ - 109.4℉)
Blood temperature accuracy
  • ± 0.1℃
Injection temperature
  • 0℃ - 27℃ (32℉ - 80.6℉)
ECG
ECG
Lead type
  • 3-lead or 5-lead selectable
Lead selection, 3-lead
  • I, II, III
Non-invasive blood pressure (NBP)
Non-invasive blood pressure (NBP)
Method
  • Automatic oscillometric
Parameters
  • SYS/DIA/MAP/Pulse Rate
See all specifications
ECG
ECG
Lead type
  • 3-lead or 5-lead selectable
Lead selection, 3-lead
  • I, II, III
Lead selection, 5-lead
  • I, II, III, aVR, aVL, aVF, V
HR measurement
  • Adult / pediatric: 15 bpm - 300 bpm Neonatal: 15 bpm - 300 bpm Step: 1 bpm
HR accuracy
  • ±5 bpm or ±1 %, whichever is greater
Arrhythmia
  • 21 calls
ST measurement range
  • -2.5 mV - +2.5 mV
Waveform speed
  • 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s
Gain selection
  • x 1/4, x 1/2, x 1, x 2, x 4, Auto
Pacemaker detection
  • Yes
Protection
  • Against electrosurgical interference and defibrillation
Non-invasive blood pressure (NBP)
Non-invasive blood pressure (NBP)
Method
  • Automatic oscillometric
Parameters
  • SYS/DIA/MAP/Pulse Rate
Operating mode
  • Manual/Auto/STAT
Auto measure intervals
  • 3, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes
Units
  • mmHg/kPa
Cuff pressure range, adult / pediatric
  • 0 - 300 mmHg ( 0 kPa - 40.0 kPa)
Cuff pressure range, neonate
  • 0 - 150 mmHg ( 0 kPa - 20.0 kPa)
Systolic measurement range, adult/ pediatric
  • 30 mmHg - 254 mmHg (4.0 kPa - 33.9 kPa)
Systolic measurement range, neonate
  • 30 mmHg - 135 mmHg (4.0 kPa - 18.0 kPa)
Diastolic measurement range, adult / pediatric
  • 10 mmHg - 220 mmHg (1.3 kPa - 29.3 kPa)
Diastolic measurement range, neonate
  • 10 mmHg - 110 mmHg (1.3 kPa - 14.7 kPa)
MAP measurement range, adult / pediatric
  • 20 mmHg – 235 mmHg (2.7 kPa – 31.3 kPa)
MAP measurement range, neonate
  • 20 mmHg – 125mmHg (2.7 kPa – 16.7kPa)
Accuracy, maximum standard deviation
  • 8 mmHg (1.1 kPa)
Accuracy, mean error
  • ±5 mmHg (±0.7 kPa)
Pulse rate range
  • 40 bpm – 240 bpm
Pulse rate accuracy
  • ±5bpm or ±5%, whichever is greater
SpO2 (Philips SpO2 technology)
SpO2 (Philips SpO2 technology)
Measurement range
  • 0 - 100 %
Accuracy
  • 70 % - 100 %, depends on sensor; 0 - 69 %, unspecified
Waveform speed
  • 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Pulse rate range
  • 30 bpm - 300 bpm
Pulse rate accuracy
  • ±2 bpm or ±2%, whichever is greater
Perfusion index
  • Yes
Respiration (RESP)
Respiration (RESP)
Measurement method
  • Thoracic impedance
Measurement range
  • 0 rpm - 150 rpm
Accuracy
  • 0rpm – 120rpm: ±1 rpm; 121rpm – 150rpm: ±2 rpm
Waveform speed
  • 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s Accuracy undefined
Gain selection
  • x 1/2, x 1, x 2
Apnea alarm
  • Yes, 10 - 60 s
Work mode
  • Auto or manual (threshold)
RESP lead
  • RA-LL
Temperature (TEMP, 2-channel)
Temperature (TEMP, 2-channel)
Measurement range
  • 0 - 50℃ (32℉ - 122℉)
Resolution
  • 0.1℃ (0.2℉)
Accuracy
  • ±0.1℃ (±0.2℉) (without sensor)
Units
  • ℃ / ℉
Minimum measuring time
  • Attachable skin surface probe: < 10 minutes Esophageal/rectal probe: < 2 minutes
Capnography (etCO2, optional)
Capnography (etCO2, optional)
Method
  • Microstream, infrared absorption (Oridion)
Parameters
  • awRR, etCO₂, inCO₂
Measurement range
  • 0 - 99 mmHg (0 kPa - 13.2 kPa)
Accuracy+C781, 0 – 38 mmHg (0 kPa – 5.1 kPa)
  • ±2 mmHg (±0.28 kPa)
Accuracy, 39 mmHg – 99 mmHg (5.2 kPa – 13.2 kPa)
  • ± (5% of reading + 0.08% for every 1 mmHg (0.13 kPa) above 38 mmHg (5.1kPa)
awRR range
  • 0-150 rpm
awRR accuracy, 3 rpm – 70 rpm
  • ±1 rpm
awRR accuracy, 71 rpm – 120 rpm
  • ±2 rpm
awRR accuracy, 121 rpm – 150 rpm
  • ±3 rpm
Invasive blood pressure (IBP, 2-channel, optional)
Invasive blood pressure (IBP, 2-channel, optional)
Parameters
  • SYS/DIA/MAP/Pulse Rate
Measurement range
  • -50 - 400 mmHg (-6.6 kPa - 53.3 kPa)
Accuracy
  • ±4 mmHg (0.53 kPa) or ±4 % of reading, whichever is greater
Waveform speed
  • 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Resolution
  • 1 mmHg (0.13 kPa)
Units
  • mmHg/kPa/cmH₂O
Transducer sensitivity
  • 5 uV/V/mmHg
Pulse rate range
  • 30 bpm – 254 bpm
Pulse rate accuracy
  • ±2bpm or ±2%, whichever is greater
Sampling rate
  • 62.5 samples per second
Recorder (optional)
Recorder (optional)
Type
  • Built-in thermal recorder, 3 channels
Print mode
  • Real-time recording, timed recording, alarm-activated recording
Print speed
  • Auto, 12.5 mm/s, 25 mm/s, 50 mm/s
Display
Display
Type
  • Color TFT LCD, 4:3
Size
  • 10.4+611:631"
Resolution
  • 800 x 600 pixels
Channels
  • Max 11 channels (auto waveform channel height adjustment)
Power supply
Power supply
AC power input
  • 100 - 240 VAC, 50/60 Hz
Battery
  • Rechargeable Li-Ion battery Maximum 2.5 hour continuous monitoring
Weight and dimensions
Weight and dimensions
Net weight
  • Approx. 3.5 kg without battery
Dimensions (w x d x h)
  • 316 mm x 265 mm x 131 mm (12.5 in. x 10.5 in. x 5.2 in.)
Safety approval and quality system
Safety approval and quality system
Safety standard
  • IEC 60601-1-2:2014
Electromagnetic environment
  • IEC 60601-1-2:2000/A1:2014
Quality system
  • ISO9001 & ISO13485 certified CE marking according to the Council Directive 93/42/EEC
Water proof
  • IPX1
Data review and storage
Data review and storage
Data review and storage
  • 1600- NBP data, 1200 hr trend graph, 120 min full disclosure ECG 1, 200 - alarm & arrhythmia events
External interface (standard)
External interface (standard)
External interface
  • ECG analog output VGA output Nurse call LAN USB
Cardiac Output (optional)
Cardiac Output (optional)
Measurement method
  • Right heart thermodilution
Measurement range
  • 0.1 l/min - 20.0 l/min
Measurement accuracy
  • ±0.2 l/min or ±10 %, whichever is greater
Blood temperature range
  • 27℃ - 43℃ (80.6℉ - 109.4℉)
Blood temperature accuracy
  • ± 0.1℃
Injection temperature
  • 0℃ - 27℃ (32℉ - 80.6℉)

You are about to visit a Philips global content page

Continue

You are about to visit a Philips global content page

Continue

Our site can best be viewed with the latest version of Microsoft Edge, Google Chrome or Firefox.

Pristupate Philipsovim hrvatskim internet stranicama zdravstvene skrbi
Please select the checkbox

Ove internet stranice namijenjene su isključivo osoblju koje se koristi medicinskim proizvodima u obavljanju svoje djelatnosti, uključujući zdravstvene radnike, osoblje koje postupa u ime zdravstvenih institucija i/ili osoblje koje se profesionalno bavi trgovinom medicinskim proizvodima.

Spadate li u kategoriju osoba koje udovoljavaju gornjim kriterijima?

Da Ne